INDUCTORS  [Wire-wound Metal Power Inductors MCOIL™ LLEU series for Medical Devices classified as GHTF Classes A or B (Japan Classes I or II)]

产品规格

Status Mass Production (Preferred)
Inductance 2.2 uH ± 20 %
Case Size (EIA/JIS) 1008/2520
Rated Current (max) 2.5 A
Saturation Current (max) 3 A (⊿L=30%)
Saturation Current (typ) 3.4 A (⊿L=30%)
Temperature Rise Current (max) 2.5 A (⊿T=40℃)
Temperature Rise Current (typ) 2.8 A (⊿T=40℃)
DC Resistance (max) 76 mΩ
DC Resistance (typ) 66 mΩ
Operating Temp. Range -40 to +125 ℃
(Including-self-generated heat)
Temperature characteristic
(Inductance change)
± 15 %
Dimension L 2.5 ±0.2 mm
Dimension W 2.0 ±0.2 mm
Dimension T Max 1.0 mm
Dimension e 0.8 ±0.3 mm
Measuring Frequency 1 MHz
RoHS Compliance (10 subst.) Yes
REACH Compliance (251 subst.) Yes
Halogen Free Yes
Soldering Reflow
Standard Quantity Taping Embossed 3000pcs
Quantity
旧型号 :
Distributor Quantity Buy
Powered by netComponents

外观

特征

Use of metallic magnetic materials which has excellent DC bias characteristic

Low core loss

Low Rdc

主要用途

For Medical Devices classified as GHTF Classes A to B (Japan Classes Ⅰ to Ⅱ)

For small DC/DC converter

产品資料

 

模拟数据

链接

 

关于产品的环保证明书

The saturation current value is the DC current value having inductance decrease down to 30%. (at 20℃)
The temperature rise current value is the DC current value having temperature increase up to 40℃. (at 20℃)
Please contact our sales staff when ordering or inquiring the details about products on our website.