INDUCTORS  [Wire-wound Metal Power Inductors MCOIL™ LLAP series for Medical Devices classified as GHTF Classes A or B (Japan Classes I or II)]

Specifications

Status Mass Production (Preferred)
Inductance 1.5 uH ± 20 %
Case Size (EIA/JIS) 1008/2520
Rated Current (max) 2.4 A
Saturation Current (max) 3 A (⊿L=30%)
Saturation Current (typ) 3.4 A (⊿L=30%)
Temperature Rise Current (max) 2.4 A (⊿T=40℃)
Temperature Rise Current (typ) 2.6 A (⊿T=40℃)
DC Resistance (max) 78 mΩ
DC Resistance (typ) 68 mΩ
Operating Temp. Range -40 to +125 ℃
(Including-self-generated heat)
Temperature characteristic
(Inductance change)
± 15 %
Dimension L 2.5 ±0.2 mm
Dimension W 2.0 ±0.2 mm
Dimension T Max 1.0 mm
Dimension e 0.5 ±0.3 mm
Measuring Frequency 2 MHz
RoHS Compliance (10 subst.) Yes
REACH Compliance (247 subst.) Yes
Halogen Free Yes
Soldering Reflow
Standard Quantity Taping Embossed 3000pcs

Appearance

To Higher Specification

Smaller
Lo-Rdc Lower
Hi-Curr.

Features

Use of metallic magnetic materials which has excellent DC bias characteristic

Main Applications

For Medical Devices classified as GHTF Classes A to B (Japan Classes Ⅰ to Ⅱ)

For small DC/DC converter

Document

 

Simulation data

Links

 

RoHS and REACH Certificate of Compliance

Characteristic value graphs

The saturation current value is the DC current value having inductance decrease down to 30%. (at 20℃)
The temperature rise current value is the DC current value having temperature increase up to 40℃. (at 20℃)
Please contact our sales staff when ordering or inquiring the details about products on our website.