LMQEA251818T470K

(Previous Part Number LBR2518T470K8)

INDUCTORS

[Wire-wound Ferrite Inductors LMQB/LMQC/LMQE series for Medical Devices classified as GHTF Class C (Japan Class III)]


Appearance

Specifications

Status Mass Production (Preferred)
Inductance 47 uH ± 10 %
Case Size (EIA/JIS) 1007/2518
Rated Current (max) 0.12 A
DC Resistance (max) 1.092 Ω
DC Resistance (typ) 0.84 Ω
Self Resonant Frequency (min) 11 MHz
Operating Temp. Range -40 to +105 ℃
(Including-self-generated heat)
Temperature characteristic
(Inductance change)
± 20 %
Dimension L 2.5 ±0.2 mm
Dimension W 1.8 ±0.2 mm
Dimension T 1.8 ±0.2 mm
Dimension e 0.5 ±0.2 mm
Measuring Frequency 2.52 MHz
RoHS Compliance (10 subst.) Yes
REACH Compliance (242 subst.) Yes
IEC62474 (Ver. D29.00) Compliance Yes
Halogen Free Yes
Soldering Reflow
Standard Quantity Taping Embossed 2000pcs
Rated Current : The maximum DC value having inductance decrease within 20 % and temperature increase within 20 degC by the application of DC bias.
Please contact our sales staff when ordering or inquiring the details about products on our website.

Features

Wound Chip Inductors having wide line-up, which are suitable
for any circuit designs

Main Applications

For Medical Devices classified as GHTF Classes C (Japan Classes Ⅲ)

They are suitable for an anti-noise measure on the power supply circuit

Note: Please be sure to contact us for further information in advance
when the products are used for automotive electronic equipment.

Document

To Higher Specification

Smaller
Hi-Temp. Lower
Hi-Curr.

Links

RoHS and REACH Certificate of Compliance

Characteristic value graphs

{{title}}