(旧品番 CBC2518T470M)
INDUCTORS
[Wire-wound Ferrite Power Inductors LLQN/LLQPA series for Medical Devices classified as GHTF Classes A or B (Japan Classes I or II)]
| Status | Mass Production (Preferred) |
|---|---|
| Inductance | 47 uH ± 20 % |
| Case Size (EIA/JIS) | 1007/2518 |
| Rated Current (max) | 0.24 A |
| Saturation Current (max) | 0.24 A (⊿L=30%) |
| Temperature Rise Current (max) | 0.29 A (⊿T=40℃) |
| DC Resistance (max) | 2.47 Ω |
| DC Resistance (typ) | 1.9 Ω |
| Self Resonant Frequency (min) | 12 MHz |
| Operating Temp. Range | -40 to +105 ℃ (Including-self-generated heat) |
| Temperature characteristic (Inductance change) |
± 25 % |
| Dimension L | 2.5 ±0.2 mm |
| Dimension W | 1.8 ±0.2 mm |
| Dimension T | 1.8 ±0.2 mm |
| Dimension e | 0.5 ±0.2 mm |
| Measuring Frequency | 2.52 MHz |
| RoHS Compliance (10 subst.) | Yes |
| REACH Compliance (251 subst.) | Yes |
| Halogen Free | Yes |
| Soldering | Reflow |
| Standard Quantity | Taping Embossed 2000pcs |